R-123 requires about 6 times the gas flow rate (cfm/ton) of R- 134a, which means that the suction and discharge piping must also be six times larger. Using R-134a allows McQuay to provide you with a smaller footprint chiller. Table 1: Centrifugal Models & Possible Applications Application McQuay Model

Mcquay model number tonnage. Things To Know About Mcquay model number tonnage.

We can determine the nominal size of Luxaire furnace system by examining the model number. Tonnage is a measure of BTU's in 12,000 BTU increments. For example a 1 ton system would have 12,000 BTU's. A 2.5 ton system would have 30,000 BTU's. From the Luxaire furnace model number above, with the effeciency rating (AFUE) 80%.The Goodman Air Conditioner model number is usually contained in 12 digit code. The model number includes three digits starting with zero for the nominal cooling capacity of the unit. The three-digit number shows the total capacity of the unit. We can measure it in Thermal British units. You can find the tonnage of your AC based on the model ...R. Page 2 / Catalog 1160. Vertical water source heat pump units. Features: m High efficiency. EERs from 10.4 to 12.0 COPs from 3.8 to 4.0. m Performance rated with ISO Standard 13256-1. m Safety agency listed with CETL. m Multiple panels for easy accessibility to compressor and fan sections. m Removable fan motor/wheel assembly. m Two return ...Complete each section bottom and top before attaching additional sections. McQuay IM 672-3... Page 6 5/16"-18 × 1" bolt. Once the bolt is in place, secure the bracket to the adjoining section with a 1/4 × 1" drill screw. Repeat the same procedure on both corners of the unit.

Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong KongFind Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong KongRuby: 972-777-6574. Jamey: 214-755-8019. [email protected]. Our Location. Our main service facility is located in Dallas, Texas. We ship anywhere in the United States, Mexico, Canada, South America and Internationally. Surplus …

All fields. description: 2004 McQuay Air Cooled Chiller 130 Ton. Model AGZ-130BS. S/N STNE04109521, 460 /60/3. This chiller is factory new used only for in house testing. Has 6 scroll compressors and is capable of producing glycol at 0 F. name: 2004 McQuay Air Cooled Chiller 130 Ton Model AGZ-130BS. From genemco.com

1997 McQuay Air Cooled Chiller- 90 Ton. Model ALS090, S/N 57G8140101. (1) Compressor: 130 hp motor, 343 LRA, 208-230 V, 3 phase. (8) Condenser fan motors: 1.5 hp, 5.8 LRA, 208 V, 3 phase. (1) Crankcase heater: 1.7 LRA, 115 V, 1 phase. Requires min 410 amp circuit breaker and 700 amp fuses. Uses 180 lbs. of refrigerantEngineered HVAC Solutions for Alaska - Stinebaugh & CompanyPage 1 Installation, Operation, IOM 1210-1 and Maintenance Manual Group: Chiller Part Number: IOM1210-1 Date: August 2014 Magnitude ® Magnetic Bearing Centrifugal Chillers Model WMC, C Vintage 125 to 400 Tons (440 to 1400 kW) HFC-134a Refrigerant 50/60 Hz...; Page 2: Table Of Contents ©2014 Daikin Applied. Illustrations and data cover the …Whether you need to make a warranty claim or find replacement parts, there are plenty of reasons why you may need to find the model number for your GE motor. Here are several helpf...McQuay 6- to 10-ton horizontal units have a common cabi-net size and common water, condensate, and duct connection locations for easier and more efficient installation. The cabinet is constructed of unpainted, G-60 galvanized steel. Large panels provide access to the fan/motor compart-ment and the compressor/control compartment. The interiors of

6 McQuay Cat 565-1 Introduction IntroductionQuality McQuay air handling equipment has been respected and regarded as high quality for nearly 60 years. McQuay has taken a major step in redefining the indoor air handler with the Vision air handler. Demands for improved indoor air quality, low sound, high operating efficiency and smaller mechanical

3D printers build models in layers, which you can see if you look at a model closely. If you want a smoother, shinier surface, you can achieve injection mold-like quality with a ...

McQuay offers a complete line of condensing units from 12 to 120 tons (42 to 420 kW). This manual covers Model ALP 012D through ALP 019D, 12 to 20 tons (42 to 70 kW). Information on other sizes is contained in Product Manuals PM ALP2-1, PM ACZ, PM ACR. The McQuay ALP air-cooled condensing units offer efficiency, flexibility, reliability and ...R-123 requires about 6 times the gas flow rate (cfm/ton) of R- 134a, which means that the suction and discharge piping must also be six times larger. Using R-134a allows McQuay to provide you with a smaller footprint chiller. Table 1: Centrifugal Models & Possible Applications Application McQuay ModelGROUP mcQUAY..P&Af'EX Inc. t36001ndustriaiParkB!vd.P.O.Box1551,Minneapolis,Mn.55440 . ND ... Available in three model types for horizontal and vertical unit arrangements: LSL VERTICAL UNIT ... -----NUMBER OF FANS IN STANDARD UNIT LYF-VENTILATING FAN SECTION LHD …McQuay Central Air Conditioner. Metal Grille & Universal Design. More convenient for market stocks and spare part stocks. High Efficiency Compressor. Low levels of electricity consumption. Universal Communication. 24V universal communication connection, safe and simple. Multiprotection. High & low pressure protection.IM307-4: PEH, PHH 050-126 Single Compressor Centrifugal Chillers. Title. IM307-4: PEH, PHH 050-126 Single Compressor Centrifugal Chillers. Created Date. 1/21/2014 8:20:35 AM.

Catalog 1355-10 Applied Packaged Terminal Air Conditioner with Top-Mounted Hydronic Heat 16" × 42" Model PDAN Unit Sizes 007 - 017 • R-410A RefrigerantEvaporator Model Number CE 063 J AY 18 R Motor HP (X10) Impeller Type: J or K Impeller Size:060= 6.0" 063= 6.3" Gear Ratio (see Gears table for list) Compressor Model Number Compressor Type: CE= Centrifugal Hermetic PE 200 Unit Model Number Unit Type: PE- a single compressor, hermetic centrifugal chiller. Nominal Tonnage Unit …The date of production/manufacture or age of AAF brand HVAC equipment can be determined from the serial number located on the data plate. Note: Traditional heating and cooling systems no longer manufactured under AAF or AAF-McQuay brand names. Parent Company: AAF International and AAF-Flanders, a subsidiary company of Daikin Industries.McQuay offers a complete line of condensing units from 12 to 120 tons (42 to 420 kW). This manual covers Model ALP 012D through ALP 019D, 12 to 20 tons (42 to 70 kW). Information on other sizes is contained in Product Manuals PM ALP2-1, PM ACZ, PM ACR. The McQuay ALP air-cooled condensing units offer efficiency, flexibility, reliability and ...1994 McQuay Water-Cooled Chiller- 320 Ton. Model: PEH079. S/N: 5ZE81006-00. Style: 9572513010. Liquid chiller; self-contained unit. R-134a only. Compressor hours: 9812; compressor starts: 1814. Overall dimensions for chiller: 234.5 in. L x 46 in. W x 72 in. H. This unit was the East Campus Chiller running two dorms at.This Used MCQUAY 50 Ton Water Cooled Chiller has been inspected and is located in our facility in Bridgeport, Tx. We Buy and We Sell New and Used Chillers, Cooling Towers and Equipment. ... Model Number: WGZ050AW27-ER10; Serial Number: STNU071100075; Year: 2007; 50 Tons Nominal Cooling; 460V/3Ph/60Hz; Refrigerant: R-22; Scroll Compressors;

On February 13, Computer Modelling Group releases earnings for Q3.Wall Street analysts expect Computer Modelling Group will release earnings per s... Computer Modelling Group will ...

Information covers McQuay International products at the time of publication ... These units provide the lowest dollar per ton price. Ratings begin on page 19. High Efficiency, designated by a "5" as the last digit in the model number (such as AGS 175C) are designed for operation up to 125 °F without unloading for leaving water ...Look for the 7th and 8th digits, or maybe 8th and 9th digits, of the model number. It will be a number divisible by 6 or 12, and represents the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons.1994 McQuay Water-Cooled Chiller- 320 Ton. Model: PEH079. S/N: 5ZE81006-00. Style: 9572513010. Liquid chiller; self-contained unit. R-134a only. Compressor hours: 9812; compressor starts: 1814. Overall dimensions for chiller: 234.5 in. L x 46 in. W x 72 in. H. This unit was the East Campus Chiller running two dorms atQuiet, 3-speed permanent split capacitor motor. High performance forward curved centrifugal fan wheels. Split design fan housings or single-piece fan housings with separate inlets for exceptional serviceability. Single power location for field wiring connections in unit elec-trical box.Model MPS. Daikin Maverick II commercial packaged rooftop systems, from 15 to 75 tons, use ozone-friendly R-410A refrigerant and are designed for new, retrofit or replacement applications on one to three-story buildings like offices, schools, libraries, and strip malls. Arriving as a complete packaged solution, Maverick II maximizes your design ...McQuay Water Chiller. Model ALR195C-X. Approximate capacity: 195 nominal tons using R-22 based on conditions of 95°F ambient air and a 10°TD change between 55°F and 45°F. Test pressure hi/lo: 380/150 psig. Max relief pressure: 450 psig. (4) 8-cylinder compressors, 60 Hp each 460V 60 Hz 3 phase. (14), 26 in. dia. fans and motors: 1hp, 460V ...

Features. Stable operation with entering condenser water temperatures 30°F (16.7°C) below leaving chilled water set point. Offers exceptional efficiency with below 0.100 kW/ton at part load. Less complex magnetic-bearing technology for superior reliability and performance compared to refrigerant-lubricated, ceramic ball bearings.

1997 McQuay Air Cooled Chiller- 90 Ton. Model ALS090, S/N 57G8140101. (1) Compressor: 130 hp motor, 343 LRA, 208-230 V, 3 phase. (8) Condenser fan motors: 1.5 hp, 5.8 LRA, 208 V, 3 phase. (1) Crankcase heater: 1.7 LRA, 115 V, 1 phase. Requires min 410 amp circuit breaker and 700 amp fuses. Uses 180 lbs. of refrigerant

View and Download McQuay ALR 110F product manual online. Air-Cooled Reciprocating Water Chillers, 110 to 150 Tons, 380 to 525 kW, R-22, 60 Hertz. ALR 110F chiller pdf manual download. Also for: Alr 120f, Alr 140f, Alr 130f, Alr 135f, Alr 145f, Alr 150f.Install a tee fitting with a leak-tight removable cap in each tube near the sensor fitting. This facilitates connecting a manometer or pressure gauge if testing is required. Use different colored tubing for the duct pressure (HI) and reference pressure (LO) taps, or tag the tubes. McQuay recommends 1/8" ID tubing.First, determine the type of equipment from the two categories shown below. The photos and diagrams will help you locate the model and serial numbers of your equipment, if they are not found on your original warranty or sales invoice. Split Systems. Two Model and Serial Tags identify Split System Equipment. Package Systems. McQUAY CENTRIFUGAL OPERATING LOG. .23 McQUAY SERVICE PROGRAMS 24.17, 18 18 18 18 18 18 19 19 INTRODUCTION GENERAL DESCRIPTION The McQuay Model PEH Centrifugal Water Chillers are com-plete, self-contained, automatically controlled water chilling units. Each unit is completely assembled and factory tested prior to shipment. R. Page 2 / Catalog 1160. Vertical water source heat pump units. Features: m High efficiency. EERs from 10.4 to 12.0 COPs from 3.8 to 4.0. m Performance rated with ISO Standard 13256-1. m Safety agency listed with CETL. m Multiple panels for easy accessibility to compressor and fan sections. m Removable fan motor/wheel assembly. m Two return ...Available from 600 to 2500 tons, dual compressor chillers offer excellent full-load and part-load performance for increased energy savings. This industrial chiller occupies less floor space than having multiple single compressor chillers, while delivering the equivalent combined capacities. Using R-134a or R-513A refrigerant, these chillers ...This McQuay model WMC Centrifugal water chiller is a complete, self-contained, automatically controlled, fluid-chilling unit featuring dual Oil-Free Centrifugal Magnetic Bearing technology. This used 2006 McQuay 290 Ton Water-Cooled Chiller is located in our facility in Dallas, Texas and is ready to ship to your location. NEVER CHANGE OIL IN YOUR CHILLER AGAIN!!! McQuay WMC: Brochure McQuay ...Detailed model information for the MCQUAY 40 Ton Water Cooled Chiller. Find Industrial and Mechanical Equipment and salvage on Texas Used Chillers. ... Model Number: WGZ040CW27-ER10; Serial Number: STNU080200191; Year: 2008; 40 Tons Nominal Cooling; 460V/3Ph/60Hz; Refrigerant: R-410A;Find many great new & used machinery deals and get the best price for 800 Ton, McQuay #PEH126BCBB, package chiller, water cooled, R-134A, Microtech 200 controls, s/n at Surplus Record. ... > Show Seller's Phone Number 866-740-5490 Let the seller know you found their listing on ... Used 800 ton McQuay package chiller, model PEH126BCBB, water ...Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong Kong

MCQUAY® HVAC age. How to determine the date of production/manufacture or age of McQuay® HVAC Systems. The date of production/manufacture or age of McQuay® HVAC equipment can be determined from the serial number or MFG. DATE located on the data plate.It'll look like the image below. Up near the top of the label, you see the model number (M/N) and serial number (S/N). The model number is where you can find the number you're looking for. Not all manufacturers do this, but most will give you a 2 or 3 digit section that tells you how many thousands of BTU/hour your air conditioner can move ...Model Number Reference Guide Revision: April 2004. MODEL NUMBER INDEX BEGINNING MODEL PRODUCT PAGE FD, UD Deluxe System 2 1 ... Deluxe System 2 Tonnage Chart Tonnage 6 8 10 15 20 22 Air Cooled 075A 114A 125A 199A 245A 290A Water Cooled 086W 127W 138W 219W 267W 315WInstagram:https://instagram. sturniolo older brothermee6 nftslodi stadium 12 theaterap bio 2022 mcq get special offers & news from parts town. I Want In. 800.438.8898. Parts Town has the largest in-stock inventory of genuine OEM McQuay parts with fast same day shipping until 9pm ET. Find the part you need today. kumon level i answer bookbanksville plaza model type w = water to water heat pump configuration unit size 036 - e,f,g,h revision level a = current 036 b = current 060, 120, 170, 340 voltage controls cabinet insulation 1 = extended range hot water generator options (tmw036-120 only) c = copper source water coil options n = cupro-nickel c = copperApr 8, 2019 · Here’s a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. And this is another one for a 2 ton system. If you are unsure whether you have found the right two numbers, you can double-check it by looking for the “RLA” rating on the data plate. sono bello nyc Available from 300 to 1200 tons, single compressor centrifugal chillers offer excellent full-load and part-load performance for increased energy savings and an excellent life cycle return on your investment. Using R-134a or R513A refrigerant, these chillers easily integrate with building automation systems, are seismic compliant, quiet and have ...McQuay was founded in the United States in 1933 and has been supplying and servicing equipment for air conditioning, heating and ventilation systems, as well as manufacturing radiators and heat exchangers. ... I also don't have the full model number on the sticker so its difficult to find. Anything will help thank you! chad M/N - LCA150 SM S/N ...